2017 Pingtan International Ocean Travel and Leisure Sports Expo will be opened in June

On August 23, 2016, the State Council issued the "State Council's Reply on the Construction Plan for Pingtan International Tourism Island." Pingtan has officially become China's second international tourism island. The development of Pingtan thus opened a new page. As an international tourism island, Pingtan is rich in tourism resources and has unlimited potential for the development of marine tourism and marine leisure sports. Pingtan’s unique location is the most important window of the mainland’s proximity to Taiwan and the important economic and cultural exchanges between Taiwan’s southeastern China and Taiwan.

In June 2016, approved by the State Oceanic Administration and the People's Government of Fujian Province, the China Pacific Society, the China Ocean Engineering Consulting Association, the State Oceanic Administration Island Research Center, the Fujian Province Pingtan Comprehensive Experimental Area Management Committee, and the Fujian Provincial Department of Marine and Fisheries The first "Pingtan International Marine Leisure Sports Expo" was successfully held in Pingtan. It is reported that in order to further promote the construction of Pingtan International Tourism Island, the second exposition will be held on June 2-4, 2017 in the Pingtan Taiwan Commodity Tax Free Market Exhibition Center. This expo has added elements of marine tourism that are closely related to the marine leisure movement, and has been expanded to the “2017 Pingtan International Oceanic Tourism and Leisure Sports Expo” (hereinafter referred to as the “Expo”). At the same time, on the basis of the successful holding of the first Expo, it will be more international and professional.

The expo will contact the China Tourism Association, China Tourism Association, the United Nations World Tourism Organization, South Pacific Tourism Organization, China Recreational Fishing Association, China Diving Sports Association, China Motorboat Sports Association, China Navigation Association, Fujian Fishing Association, Fujian The Leisure and Diving Sports Association of China, the Chinese Association of Marine Photographers, the Taiwan Strait-Friendly Exchange Association, the Taiwan Association for the Development of Marine Leisure Sports and other institutions have jointly established the famous brand of exhibition on the west coast of the Taiwan Strait.

This expo will set up three core display areas: the Ocean Travel Exhibition Area, the Ocean Leisure Sports Exhibition Area, and the Virtual Reality Sports Display Area, which specifically include tourism resources, tourism commodities, boat sports, sea fishing sports, diving sports, surfing sports, and outdoor sports. Recreational activities such as cycling, RV recreation, and simulated golf, virtual surfing, virtual bike sports, etc., various sports experiences, various VR tours, games, entertainment experiences, smart running shoes, and a series of online and offline product displays.

The Expo has received strong support from more than 30 comprehensive media and nearly a hundred industry media from the central and local governments. The success of the Expo will provide a strong propaganda and promotion role for the construction of Pingtan International Tourism Island.

At present, the preparatory work of the Expo is progressing in an orderly manner.


Power Meter 2 Rates

Power Meter is a monitoring and testing instrument which determines the power consumption of a connected appliance and the cost of the electricity consumed.

Installing the batteries

Install 3.6V rechargeable Battcrics(NI-MH) . The purpose of the batteries is to store the total electricity and mcinory setting.

Resetting

If an abnormal display appears or the buttons produce no response, the instrument must be reset. To do this,press the RESET button.

Display Mode

Entire LCD can be displayed for about 1 minute and then it automatically gets into Model. To transfer from one mode to the other, press the FUNCTION button.

Mode 1: Time/Watt/Cost Display Display duration(how long) this device connect to power source.LCD on first line shows 0:00 with first two figures mean minutcs (2 figures will occur while occur at 10 min) and the rest shows seconds. After 60mins, it displays 0:00 again with first two numbers meas hour(2 figures will occur at 10hours) and the rest shows minutes. The rest can be done in the same manner which means after 24 hours, it will rc-caculatc. LCD on second line displays current power which ranges in 0.0W~9999W. LCD on third line displays the current electricity costs which ranges in 0.0cost~9999cost. It will keep on O.OOcost before setting rate without other figures.

Mode 2: l ime/Cumulative electrical quantity Display Display duration(how long) this device connect to power source.

LCD on first line shows 0:00 with first two figures mean minutes(2 figures will occur while occur at 10 min) and the rest shows seconds. After 60mins, it displays 0:0() again with first two numbers meas hour(2 figures will occur at 10hours)and the rest shows minutes. The rest can be done in the same manner which means after 24 hours, it will re-caculate. LCD on second line displays current cumulative electrical quantity which ranges in 0.000K WH 〜 9999KWII without other figures. LCD on third line displays''DAY''- "1 "will be showed on numerical part(thc other three figures will be showed at carry) which means it has cumulated electrical quantity for 24hours(one day). The rest can be done in the same manner untial the maximal cumulative time of 9999 days.

Mode 3: Time/Voltage/Frequency Display LCD on first line displays the same as Mode 1 dones. LCD on second line displays current voltage supply (v) which ranges in 0.0V~9999V .LCD on third line displays current frequency (HZ) which ranges in 0.0HZ~9999HZ without other figures.

Mode 4: Time/Current/Power Factor Display LCD on first line displays the same as Mode 1 dones.

LCD on second line displays load current which ranges in 0.0000A~9999A. LCD on third line displays current power factor which ranges in 0.00PF 〜 1 .OOPF without other figures.

Mode 5:Time/Minimum Power Display LCD on first line displays the same as Mode 1 clones. LCD on second line displays the miniinum power which ranges in 0.0W~9999W. LCD on third line displays character of "Lo" without other figures.

Mode 6: I,ime/Maximal Power Display LCD on first line displays the same as Mode 1 dones. LCD on second line displays the maximal power which ranges in 0.0W~9999W. LCD on third line displays character of "Hi" without other figures.

Mode 7: Time/Price Display LCD on first line displays the same as Mode 1 dones. LCD on third line displays the cost which ranges in O.OOCOST/KWH 〜 99.99COST/KWH without other figures.
Overload Display: When the power socket connects the load over 3680W, LCD on second line displays the"O VER LOAD" with booming noise to warn the users,( 60470643, 60469303,selectable choice)
Supplemental informations:
1: Except tt OVERLOAD , ' interface, LCD on first line display time in repitition within 24hours.
2: LCD on first line, second line or third line described in this intruction take section according to two black lines on LCD screen. Here it added fbr clarified purpose.
3. Mode 7 will directly occur while press down button "cost".
4. [UP"&''Down" are in no function under un-setting mode.
Backlight Mode:
Connect to AC power,backlight im mediately light,if not press any button,backlight will went off in 15 seconds.
When press any of the buttonsbacklight start light again. (Backlight only light when it connect to AC power,backlight cannot light if use battery)
Setting Mode
1. Electricity price setting
After keeping COST button pressed lasting more than 3 seconds(LCD on third line display system defaults price, eg O.OOCOST/KWH ),the rendered content begins moving up and down which means that the device has entered the setting mode. Then press FUNCTION button to change selection and press UP/DOWN to set what you want. (On pressing once, the figure after domical point will increase or decrease accordingly. On pressing and hold-on, figures after demical point will increase or decrease slowly in 2 seconds while figures change quickly when hold-on time exceeds 2 seconds. When hold-on time reaches 10 seconds or more, the figures after demical point will stop while the figures before demical point begin to increasing or decreasing.) After that, press FUNCTION fbr swithing, then press [UP'nd "DOWN" button again to set value which ranges in OO.OOCOST/KWH 〜 99.99COST/KWH. After setting all above, press COST to return to Mode7 or it will automatically return to Mode7 without any pressing after setting with data storage.

Power meter double rates, power meter two rates, cost rate socket, power meter cost rate, energy meter cost rate, cost socket, cost plug