Model NO.: 4x35sq. mm
Material Shape: Round Wire
Range of Application: Flame Retardant
Certification: ISO9001, CE, CCC, RoHS
Brand: Jytop
Standard: Based on DIN VDE 0276-603
Certificate: Ce, ISO 9001
Trademark: JYTOP
Transport Package: Drum or Reel
Specification: 4x35mm 2
Origin: Zhengzhou, China
HS Code: 8544492100
Model NO.: 4x35sq. mm
Material Shape: Round Wire
Range of Application: Flame Retardant
Certification: ISO9001, CE, CCC, RoHS
Brand: Jytop
Standard: Based on DIN VDE 0276-603
Certificate: Ce, ISO 9001
Trademark: JYTOP
Transport Package: Drum or Reel
Specification: 4x35mm 2
Origin: Zhengzhou, China
HS Code: 8544492100
Low Voltage LV 35MMx4 CORE xlpe insulated Underground Urd Power Cable1. Operating Characteristics
Rated voltage: 0.6/1(1.2)kV
Max. Permissible continuous operating temperature of conductor: 70° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed:
Nominal cross section of conductor ≤ 300mm2: 160° C;
Nominal cross section of conductor >300mm2: 140° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 20 times of the diameter of cable
For multi-core cable: Not less than 15 times of the diameter of cable
2. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, in tunnel, in cable trench or in conduit, unable to bear external mechanical force.
3. Manufacturing Standards
IEC 60502-1 & Chinese national standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.
Parameter of 4 CORE xlpe insulated Underground URD Power Cable
 Cable size |
 Conductor type |
Nominal thickness of PVC insulation(mm) | Nominal thickness of PVC sheath(mm) | Approx. cable overall diameter (mm) | Max. D.C resistance @ 20 0 C  (Ω/km) |
4x1.5mm 2 | RE or RM | 0.8 | 1.8 | 11.0 | 12.1 |
4x2.5mm 2 | RE or RM | 0.8 | 1.8 | 11.9 | 7.41 |
4x4mm 2 | RE or RM | 1.0 | 1.8 | 14.0 | 4.61 |
4x6mm 2 | RE or RM | 1.0 | 1.8 | 15.3 | 3.08 |
4x10mm 2 | RM | 1.0 | 1.8 | 18.4 | 1.83 |
4x16mm 2 | RM | 1.0 | 1.8 | 20.9 | 1.15 |
4x25mm 2 | SM | 1.2 | 1.8 | 21.9 | 0.727 |
4x35mm 2 | SM | 1.2 | 1.8 | 24.1 | 0.524 |
4x50mm 2 | SM | 1.4 | 1.9 | 27.6 | 0.387 |
4x70mm 2 | SM | 1.4 | 2.1 | 31.4 | 0.268 |
4x95mm 2 | SM | 1.6 | 2.2 | 36.1 | 0.193 |
4x120mm 2 | SM | 1.6 | 2.3 | 39.3 | 0.153 |
4x150mm 2 | SM | 1.8 | 2.5 | 43.5 | 0.124 |
4x185mm 2 | SM | 2.0 | 2.7 | 48.4 | 0.0991 |
4x240mm 2 | SM | 2.2 | 2.9 | 54.6 | 0.0754 |
4x300mm 2 | SM | 2.4 | 3.1 | 60.4 | 0.0601 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor Low Voltage LV 35MMx4 CORE xlpe insulated Underground Urd Power Cable
1. Operating Characteristics
Rated voltage: 0.6/1(1.2)kV
Max. Permissible continuous operating temperature of conductor: 70° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed:
Nominal cross section of conductor ≤ 300mm2: 160° C;
Nominal cross section of conductor >300mm2: 140° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 20 times of the diameter of cable
For multi-core cable: Not less than 15 times of the diameter of cable
2. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, in tunnel, in cable trench or in conduit, unable to bear external mechanical force.
3. Manufacturing Standards
IEC 60502-1 & Chinese national standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.
Parameter of 4 CORE xlpe insulated Underground URD Power Cable
 Cable size |
 Conductor type |
Nominal thickness of PVC insulation(mm) | Nominal thickness of PVC sheath(mm) | Approx. cable overall diameter (mm) | Max. D.C resistance @ 20 0 C  (Ω/km) |
4x1.5mm 2 | RE or RM | 0.8 | 1.8 | 11.0 | 12.1 |
4x2.5mm 2 | RE or RM | 0.8 | 1.8 | 11.9 | 7.41 |
4x4mm 2 | RE or RM | 1.0 | 1.8 | 14.0 | 4.61 |
4x6mm 2 | RE or RM | 1.0 | 1.8 | 15.3 | 3.08 |
4x10mm 2 | RM | 1.0 | 1.8 | 18.4 | 1.83 |
4x16mm 2 | RM | 1.0 | 1.8 | 20.9 | 1.15 |
4x25mm 2 | SM | 1.2 | 1.8 | 21.9 | 0.727 |
4x35mm 2 | SM | 1.2 | 1.8 | 24.1 | 0.524 |
4x50mm 2 | SM | 1.4 | 1.9 | 27.6 | 0.387 |
4x70mm 2 | SM | 1.4 | 2.1 | 31.4 | 0.268 |
4x95mm 2 | SM | 1.6 | 2.2 | 36.1 | 0.193 |
4x120mm 2 | SM | 1.6 | 2.3 | 39.3 | 0.153 |
4x150mm 2 | SM | 1.8 | 2.5 | 43.5 | 0.124 |
4x185mm 2 | SM | 2.0 | 2.7 | 48.4 | 0.0991 |
4x240mm 2 | SM | 2.2 | 2.9 | 54.6 | 0.0754 |
4x300mm 2 | SM | 2.4 | 3.1 | 60.4 | 0.0601 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Copper Flat Wire Rolling Machine
Copper Flat Wire Rolling Machine,Special Shaped Copper Strip Machine,Ultra Thin Copper Strip Machine,Copper Strip Annealing Equipment
Jiangsu Lanhui Intelligent Equipment Technology Co., Ltd , https://www.lanhuisolar.com