Zt18 Fuse Base Rt18 New Style

Model NO.: ZT18
Standard: UL
Rated Curerent: 50-1000A
Rated Voltage: AC 400V/500V/690V
Trademark: WEHOPE
Transport Package: Standard Export Packing
Origin: China
HS Code: 8536100000

Application

Support parts of this series fuse for AC 50Hz, rated insulation voltage up to 690V, thermal current to 125A, mainly used in electrical wiring in size to 22 x 58 as the various use categories (gG, aM, aR, etc.) fuse support pieces. Support parts of this series with a fuse withstand thermal current and expected impact of current sprint to 100KA dynamic thermal stability capabilities. Combined with a multi-phase fuse isolators function. One model RT18N the fuse on the support of about two pieces of a road into the outlet, both isolated power function; RT18L with a safety locking device, lock the load in the off state can melt pieces, to ensure that no misuse; also with fuse indicator, lights indicating fuse is blown.
This series of fuse support pieces in line with national standards GB13539.1, GB13539.2, GB13539.6, GB14048.3 Work standards and international power IEC60269-1, IEC60269-2, IEC269-1, IEC947-3.

Structural features

This series of fuse supports the suppression of shell pieces of plastic contact and mounted on a set piece after melting by riveting or welding, have a heterogeneous structure can be formed. FB15C, FB16-3J, FB19C-3J, RT19 forthe open type, other models are semi-enclosed structure. Which RT 18N, RT 18B and RT 18C in the same dimensions of the base, choose from five different sizes of the configuration fuses; RT 18N has two inlet and outlet, all the way to configure the appropriate size of the fuse body, the other way for a double break point, often open contact, a single support piece with isolated power function; RT18-based support pieces are TH35mm rail mount, which RT 18L also with safety locking device to ensure that support disconnected pieces of misuse does not occur.

Basic data

Model, rated insulation voltage, thermal current, the configuration cylinder cap fuse size, shape and size of the table shown below (n combined wide Bn = nB)

Model Equipped with fuse size Rated insulation voltage(V) Conventional Thermal Current Dimension
A1 A2 B H1 H2
ZT18-32 10*38 500/690 32 79 81 17 61 80
ZT18-32X 10*38 500/690 32 78 80 18 62 79
ZT18-63 14*51 500/690 63 102 105 26 78 105
ZT18-63X 14*51 500/690 63 97 98 27 67 93
ZT18-125 22*58 500/690 125 127 129 35 76 104
HG30-32 10*38 500/690 32 77 78 17.5 73 88

Dimension

Zt18 Fuse Base Rt18 New Style


 

Controller