LED lighting products have developed rapidly in recent years, and all lighting manufacturers have spent considerable manpower, material resources and financial resources to produce a variety of lighting fixtures . The purpose is to improve the light efficiency and extend the service life, so that the LED lighting has an optimal and perfect lighting effect.
At present, high-power LED lighting, whether it is an integrated light source or a variety of substrate patch light sources, are planar light sources. In order to achieve a certain illuminance and illumination area, LED lighting fixtures must be equipped with optics such as lenses. However, these optical devices decelerate the light source and the light beam, causing a certain amount of light loss. Especially for integrated light sources, since each PN junction illuminating beam has a certain angle, the spacing between adjacent PN junctions of the integrated light source is small, and the light beams interfere with each other to cause light loss, plus the astigmatism installed when each integrated light source is applied. The lens, which in turn produces light loss, shows that the light loss of the integrated light source lighting is large. Moreover, due to the denseness of the PN junction, the heat of the integrated integrated light source is very concentrated, which brings a considerable difficulty to the heat exhaust system of the integrated light source, so that it is difficult for the integrated light source to maintain a low light decay state. Also due to the planarity of the integrated light source, the integrated light source is difficult to configure with a low-cost reflective film and cover. For example, some high-power street lamps, in order to change the illumination area and achieve the heat-dissipating conditions, the light shell should be opened 4-5 models. In order to achieve optical effects, the optical device also has to open 2-3 models, thus not only increasing the cost, but also wasting a lot of material resources.
Various substrate patch module strip body light source
(luminous angle 360 ​​degrees)
An ideal LED light source not only has enough illuminance in a certain light area, but also needs to be bright and not glare. At the same time, it is necessary to consider the reliability and directionality of the heat generating structure when the LED is illuminated. LED lighting is commonly known as laser lighting, but there are actually problems with light glare. In order to overcome the glare and achieve a certain illumination area, some manufacturers add astigmatism lenses to some lighting fixtures, and some add various types of frosted hoods. These mirrors and hoods consume the energy of the original light source and beam, which directly causes the light source. Corresponding light loss, which affects the lighting effect, reduces the energy saving effect of the LED.

PVC Insulated Cable (Wire)

1. Product standard

The product is manufactured according to the standard of GB5023-1997 and JB8734-1998 or IEC, BS, DIN and ICEA upon request.

2. Application

The product is suitable for use in power installations, fixed wiring or flexible connections for electrical appliances with rated voltages up to and including 450/750V respectively.

3. Operating characteristics

Rated voltages of Underground Cable U0/U: 450/750V.300/500V and 300/300V.

Max .Permissible continuous operating temperature of the conductor:

227 IEC 07 (BV-90) 90℃

227 IEC 08 (RV-90) 90℃

For other types 70℃

The ambient temperature under installation should not below 0℃

The bending radius of cable:

D≤25mm ≥4D

D>25mm ≥6D

(D-Diameter of the cable )

4. Type and Designation:

Type:

227 IEC 01(BV), 227 IEC 02(RV), 227 IEC 05(BV), 227 IEC 06(RV), 227 IEC 07(BV-90), 227 IEC 08(RV-90), 227 IEC 10(BVV), 227 IEC 42(RVB), 227 IEC 52(RVV), 227 IEC 53(RVV), 227 IEC 74(RVVYP), 227 IEC 75(RVVY), BV, BLV, BVR, BVV, BLVV, BVVB, BLVVB, RVS

Designation:

227 IEC 01(BV): Single-core non-sheathed cable with rigid conductor for general purposes

227 IEC 02(RV: Single-core non -sheathed cable with flexible conductor for general purposes

227 IEC 05(BV): Single-core non -sheathed cable with solid conductor for internal wiring for a conductor temperature of 70℃

227 IEC 06(RV): Single-core non -sheathed cable with flexible conductor for internal wiring for a conductor temperature of 70℃

227 IEC 07(BV-90): Single-core non -sheathed cable with solid conductor for internal wiring for a conductor temperature of 90℃

227 IEC 08(RV-90): Single-core non -sheathed cable with flexible conductor for internal wiring for a conductor temperature of 90℃

227 IEC 10(BVV): Light PVC sheathed cable

227 IEC 42(RVB): Flat non-sheathed flexible cord

227 IEC 52(RVV): Light PVC sheathed flexible cord

227 IEC 53(RVV): Ordinary PVC sheathed flexible cord

227 IEC 74(RVVYP): Oil-proof PVC sheathed, screened flexible cable

227 IEC 75(RVVY): Oil-proof PVC sheathed, non-screened flexible cable

BV: Copper conductor PVC insulated wire

BLV: Aluminum conductor PVC insulated wire

BVR: Copper conductor PVC insulated and sheathed round cable

BVV: Copper conductor PVC insulated and sheathed round cable

BLVV: Aluminum conductor PVC insulated and sheathed round cable

BVVB: Copper conductor PVC insulated and sheathed flat cable

BLVVB: Aluminum conductor PVC insulated and sheathed flat cable

RVS: Copper conductor PVC insulated twisted flexible cord for connection

Building Wire

PVC Single Core Cable,Building Flat Wire,Flat Building Wire,Electrical Cable Wires,Underground Cable