Bidding Notice for Suzhou University Academic Building Project

Project Name Suzhou University Experimental Building Project No. GYY201309035
Name of tenderer Suzhou University
Project location Graduate city
Lot No. Tender Name Contract Content Contract Mode Contract Estimate Price
GYY20130903507 Suzhou University Experimental Building (Five Floors 5-12) Interior Decoration and Installation Interior Decoration Project Open tender 669.670000 (million)
Number of bids allowed by the enterprise: 1, Registered architect (project manager) Number of allowed bids: 1
Lot size: The building area is 10,160m2, and the project cost is about 6,966,700 yuan.
The necessary qualifications for bid applicants
1. Qualification requirements of the company: [Building and Decoration Engineering Grade 2] (inclusive) or above [Building Decoration Engineering Design and Construction Grade 2] (inclusive) or more
2. Project Director (Director) Qualification: [Building 2] or above
3. Enterprise performance requirements: From December 1, 2013 to date (according to the completion acceptance report time), the company has undertaken a public construction interior decoration project with a single contract amount of RMB 5.3 million and above.
4. Project Manager (Director) Performance: None
5. Has the ability to independently enter into contracts;
6. The bid inviter may reject the bid of the construction unit of the park as the applicant of other bad credits identified by category c or the planning and construction department of the Suzhou Industrial Park;
7. The company is not in the state that it has been ordered to suspend business, its qualifications have been cancelled, or its property has been taken over, frozen, or bankrupted;
8. The company has not been suspended from bidding due to problems such as fraudulent bid winning or serious breach of contract, major project quality, safety production accidents, etc., and was suspended within the suspension period;
9. The important content in the prequalification application is not inaccurate or falsified;
10. This project does not allow joint bidding;
11. The company has safe production conditions and obtains a safety production license;
12. It is proposed that the project manager shall have the certificate of (B) type of production safety inspection and approval certificate for the project manager;
13. The category and group of preselected contractors shall be the following: List of Suzhou City and the building decoration professional groups I and II in the Supplement List of the Park (in case of inconsistent groups, the groups in the list of park supplements shall prevail). The effective directory on the opening day is quasi;
14. Meet other conditions stipulated by laws and regulations.
15. Other conditions: 1. The person in charge of the project must meet one of the following conditions: (1) The person in charge of the project is not under construction after the change. (2) The person in charge of the project has no construction in progress after the change, and: the original contract period has expired and the date of change of filing has reached 6 months; or, the project has been suspended for more than 120 days due to non-contractor reasons, and The construction unit agrees and has gone through the change procedures of the person in charge of the project.
2. The applicant may not have one of the following circumstances: (1) an affiliate of the tenderer (unit); (2) providing design or consulting services for the preliminary preparation of the tender, except for the general contract for design and construction; (3 ) The bidders, agents, and project managers for this bid section, or the tendering agency services for the bid section; (4) The supervisor or agent or project manager or tender agency of this tender section. The same as a legal representative, mutual control or shareholding, mutual service or work; (5) with the tenderer interested parties may affect the fairness of the tender legal person, other organizations or individuals.
3. The person in charge of the project must be the employee of the company and provide it in September, October and November of 2016.

KNBL1-32 Residual Current Circuit Breaker With Over Load Protection

KNBL1-32 TWO FUNCTION : MCB AND RCCB FUNCTIONS

leakage breaker is suitable for the leakage protection of the line of AC 50/60Hz, rated voltage single phase 240V, rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will automatically cut off the power within 0.1s to protect human safety and prevent the accident due to the current leakage.
leakage breaker can protect against overload and short-circuit. It can be used to protect the line from being overloaded and short-circuited as wellas infrequent changeover of the line in normal situation. It complies with standard of IEC/EN61009-1 and GB16917.1.


KNBL1-32 Residual Current Circuit Breaker,Residual Current Circuit Breaker with Over Load Protection 1p,Residual Current Circuit Breaker with Over Load Protection 2p

Wenzhou Korlen Electric Appliances Co., Ltd. , https://www.zjmotorstarter.com